User guide

September 2009
Page 78 of 79 OmniSwitch 6400/6850/6855/9000/9000E—Release 6.4.2.R01
Hot insertion of unlike modules is not supported.
The reload ni command is not supported. Please use no power ni/power ni as an alternative.
All insertions of NI modules cannot be followed by another hot swap activity until the OK2 LED on
the inserted NI blinks green.
Hot Swap Feature Exceptions for OmniSwitch 6400/6850/6855
When removing modules from the stack (powering off the module and/or pulling out its stacking
cables), the loop back stacking cable must be present at all times to guarantee redundancy. If a module
is removed from the stack, rearrange the stacking cables to establish the loopback before attempting to
remove a second unit.
When inserting a new module in the stack, the loop back has to be broken. Full redundancy is not guar-
anteed until the loop back is restored.
Hot Swap Time Limitations for OmniSwitch
All removals of NI modules must have a 30 second interval before initiating another hot swap activity.
All insertions of NI modules must have a 3 minute interval before initiating another hot swap activity.
All hot swaps of CMM modules must have a 10 minute interval before initiating another hot swap,
reload or takeover activity.
All takeovers must have a 10 minute interval before following with another hot swap, reload or take-
over activity.
All insertions of stack elements must be done one at a time and the inserted element must be fully
integrated and operational as part of the stack before inserting another element.