Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 99
OmniSwitch 8800 Feature Exceptions
When a chassis is fully loaded with 5 SFM modules, an Amber Light indicates that the module is in
Stand-By mode.
General
Problem Reports
PR 51067
Switch based telnet client only supports a single user at a time on the OS7000. If one user already has
started using the telnet client, and a second user attempts to use the switch based telnet client at the same
time, a message will be generated informing the second user that the client is already in use.
The actual message sent is: "Telnet is already in use.".
Workaround: There is no known workaround at this time.
PR 51088
The more command is not supported on multiple user sessions on the OS7000. Therefore only one
instance may be active on a switch at a time. If a second user attempts to use more, when it is already
active, they will receive the message: more is currently in use, try again later.
Workaround: There is no known workaround at this time.
PR 52676
Blocking sockets need to be released when a remote slot goes down on the OS7000.
Workaround: There is no known workaround at this time.
PR 55967
Only terminal ID vt100 is supported on the OS7000. User must set tty terminal type to vt100 to support
some switch software that uses ASCII escape codes. Editor 'vi' is an example.
Workaround: There is no known workaround at this time.
PR 59475/59877
Changing from multiple router MAC to single router MAC mode and vice-versa requires a reboot on the
OS7000.
Workaround: There is no known workaround at this time.