User guide
Open Problem Reports and Feature Exceptions
page 94 OmniSwitch 6600/7000/8800—Release 5.1.5.R04
General
Problem Reports
PR 80799
During multiple, sequential SSH connections to an OS8800, the message "++Sorry, traces of my own
stack begin at tt ()." might print to the console.
Workaround: There is no known workaround at this time.
802.1X
Problem Reports
PR 70452
On the OS7000, even after the PC is successfully authenticated to a port, the status on the PC will show as
not authenticated when using 802.1X with XP SP-1/SP-2.
Workaround: This is a problem in the Microsoft XP driver.
PR 72546
On OS6624/6648, after the supplicant is authenticated and the port is open-global, non-supplicant on that
port will be on the supplicant's VLAN. It only supports one VLAN per port. The default should be moved
from the original default VLAN to the supplicant's assigned VLAN after the supplicant is authenticated to
the port. This behavior is different from the OS7000/8000 platform which can support more than one
VLAN per port.
Workaround: There is no known workaround at this time.
Security