User guide

Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 93
PR 75062
When running in a mixed environment consisting of OS7000's and Cisco's, the OS7000 PIMSM router
may get into a state in which the flows get disrupted. This is caused by erroneous prunes. Once in this
state, the flows will have to be completely timed out.
Workaround: There is no known workaround at this time.
PR 77055
On the OS7000, if there are multiple routes to either the RP or any of the multicast sources, PIM-SM must
be enabled on all of the interfaces.
Workaround: Enable PIM-SM on all interfaces that may be considered possible routes to either the RP or
any of the multicast sources.
PR 84167
While the CLI command show ip mroute-boundary shows the interface index, WebView displays the
Vlan Router IP address instead of interface index for the corresponding WebView page (IP Multicast/
Routing/Boundaries) on an OS8800.
Workaround: There is no known workaround at this time.