User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 91
PR 81763
On OmniSwitch 6600 series switches, when OSPF debugs are enabled from the console, after a while the
console will lockup. This is since OSPF tries to use a print from a signal handler. This is a limitation.
Workaround: Use the OSPF debugs only on telnet sessions and never on console sessions.
PR 81782
A non-ABR router generating a Type-7 LSA does not set the P-Bit in the LSA (to enable translation) if an
enabled inactive non-NSSA area exists.
Workaround: Delete or disable the inactive area.
PR 81856
On OS6600 series switches, Webview OSPF Routes page does not display the aggregated summary route
entry corresponding to the active address range configured for the area.
Workaround: There is no known workaround at this time.
PR 82004
HRE PCAM's max.collision depth of 5 causes Catalina 1.1 boards to stall on some multicast packets.
Workaround: There is no known workaround at this time.
PR 84440
On an OS6600/7000, if a redistributing router is rebooted and if after the reboot the external routes no
longer exist, max-aged lsas might remain in the data base of the redistributing router or its neighbors with
one or more neighbor retransmission list not being emptied.
Workaround: There is no known workaround at this time.
PIM-SM
Problem Reports
PR 73783
On an OS7000, a lot of register packets will stress the NI. Everything is going through software and so the
NI will be very busy.
Workaround: There is no known workaround at this time.