User guide

Open Problem Reports and Feature Exceptions
page 88 OmniSwitch 6600/7000/8800—Release 5.1.5.R04
PR 78983
Sometimes on the OS8800, if BGP flap dampening is enabled, BGP task might crash depending on a
particular flapping characteristic and setup. This is not a reproducible issue.
Workaround: No workaround exists for this issue. The OS8000 might need to be reloaded to restore
normal BGP operation.
DVMRP
Problem Reports
PR 56990
Tunnel destined flows are not displayed in the show ip multicast forwarding CLI command on the
OS7000. There is simply no room left on the line to display.
Workaround: Use the show ip mroute-next-hop CLI command instead to display tunnel endpoint infor-
mation.
Multicast Routing
Problem Reports
PR 55446
Multicast routing does not handle large multicast bursty traffic on the OS7000.
Workaround: There is no known workaround at this time.
PR 79306
Multicast streams may be momentarily disrupted during NI insertion or removal.
Workaround: This condition is temporary and all flows will resume after a few seconds.
PR 79916
Timeout of group membership may not result in a leave message being sent to an upstream device on the
OS7000.
Workaround: None, however this will only result in a small amount of bandwidth over-utilization across
the trunk. The actual member will not receive the flow and therefore clients will be unaffected.