PR 80995
On the OS8800, on takeover some NI (with linkagg confgured) may not get reset.
Workaround: Do not hotswap second generation boards with first generation boards.
PR 81061
If second generation ports are added first to an linkagg then first generation ports added, error message
gets displayed.
Workaround: Add first generation ports first then add second generation ports when using CLI.
PR 81288
On the OS7000, enabling backpressure command stop LACP packets being exchanged.
Workaround: Do not run this command with LACP configured.
PR 81416
On the OS7000, changing LACP values on run time makes the ports not join the linkagg.
Workaround: Do not change LACP values on the run time. If needed delete the port and add again to
make a modification.
PR 81531
On OS6600 series switches, sometimes multicast flow stops when linkagg ports are added and deleted
multiple times.
Workaround: There is no known workaround at this time.
PR 81650
When LACP ports with misconfiguration connected to an LACP ports which sends LACP pdus, the LACP
pdus parameters can make port join a wrong a linkagg.
Workaround: When configuring LACP values, make sure that each end of the linkagg is configured
properly.
PR 81722
If more ports are configured than the actual linkagg size, some or all ports may not join the dynamic link
aggregate.
Workaround: Do not configure more ports than the actual linkagg size.