PR 78909
On OS8800 switches, once second-generation NI port added to a linkagg, cannot add first-generation NI
port.
Workaround: Add first generation NI port first then add subsequent second generation ports, else add
them in boot.cfg and reboot.
PR 78945
Cannot add more than 14 linkagg with size 8.
Workaround: The limitation documentation is modified with correct numbers for OS7000/8800. Refer to
the limitation document for the exact numbers.
PR 79116
On the OmniSwitch 6624/6648, LACP port priority is not supported. The port priorities do not control the
order of the ports joining the aggregate.
Workaround: Do not configure port priorities.
PR 79204
On the OS7000, the LACP system priority and port priority doesn’t have any effect on ports joining the
aggregate
Workaround: Do not use port priority and system priority values in LACP as a selection criteria, these
are needed for compatibility issues.
PR 79829
On the OS7000, LACP parameters cannot be modified on run time.
Workaround: Delete the port and add when and if LACP parameters have to be changed.
PR 80033
On the OS7000, if second generation NI port comes up, then first generation NI port doesn’t join.
Workaround: When configuring mixed version NI ports, make sure first generation ports are configured
first then second generation ports are configured.
PR 80908
On the OS7000, the linkagg eni dedicated enable/disable command gives an error.
Workaround: This command is not supported any more. No need to use this command.