User guide

Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 51
PR 83996
Query Max Response Time can not be set through CLI or WebView on an OS7000.
Workaround: This can be set through SNMP variable igmpInterfaceQueryMaxResponseTime.
PR 84009
It is not possible to configure an interface as IGMPv1 through the CLI or WebView on an OS7000.
Workaround: Configure an interface as IGMPv1 through SNMP.
PR 84642
On the OS8800, static neighbors/queriers/members may have problems being applied to 10 Gig ports. The
static neighbor/querier/member command applies to the actual underlying port and does not map to the
underlying link aggregation instance.
Workaround: Apply the static neighbor/querier/member command to the underlying primary port of the
link aggregate instance.
Learned Port Security
Problem Reports
PR 71412
When Learned Port Security is configured on an OS6624/6648, traffic gets flooded until MAC addresses
are learned.
Workaround: Directly create the objects in an active state. Thereby, bypassing this problem by previ-
ously configuring together both sides of the static aggregates, with aggregation set "disable". Thus, the
"admin state" must be set to "disable" just after the creation. When the whole configuration is ready, set
the admin state to "enable" such it is by default. There is also the possibility of setting down/up ports.
Thus interfaces could be also set admin "down/up" before everything is ready.
PR 73953
With an LPS (Learned Port Security) configuration set to only allow a specific MAC on a port and when
the port receives non-authorized traffic (ARP requests), the MAC info shows that the unauthorized host is
in a "filtering" state hence all traffic should be filtered. However the ARP table learns the ARP entry for
the filtered host. ARPs should not be learned for "filtered" hosts.
Workaround: There is no known workaround at this time.