User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 47
PR 84353
Ethernet tab -> Interface Configuration -> General -> Modify (select an interface first).
Title: Modify Ethernet Network Interface
1. It accepts an invalid value such as -2 without an ERROR message.
2. The input rate is adjusted to the best value for the switch.
Workaround: 1. Do not put invalid values. 2. It is not a critical issue. (The System finds the best values
for the switch.)
PR 86084
The configuration file from 5.1.4 or older releases is not be compatible for autonegotiation if either speed
or duplex is set to non-auto.
On such releases, autonegotiation was automatically disabled and saved in the boot.cfg configuration file.
Workaround: Enable autonegotiation and save the config
PR 87050
On the OS6000, after a takeover, the "show health" command may not always display correct information
for all slots.
Workaround: There is no known workaround at this time.
PR 88037
On the OS6600, after multiple takeovers, part of the traffic might be flooded in the associated vlan.
Workaround: Flush the mac address table (no mac-address-table learned).
Flow Control
Problem Reports
PR 38896
Clause 31 of the IEEE 802.3 Specifications specifies a MAC Control Frame format consisting of Destina-
tion Address, Source Address, Type, MAC Control Opcode and Reserved (PAD) field. The MAC Control
Frames are transmitted correctly as specified by the standard. However, during receive, operation checks
for the validity of all the fields as specified in the standard, except the 'reserve' field which is specified as
all 'zeroes' on the OS7000.
Workaround: There is no known workaround at this time.