User guide
Open Problem Reports and Feature Exceptions
page 44 OmniSwitch 6600/7000/8800—Release 5.1.5.R04
PR 84528
The WebView help pages for the Console Port incorrectly say that the Input/Output states are None,
Enabled, and Disabled when in reality the states are None, ON, and OFF.
Workaround: There is no known workaround at this time.
PR 84616
When changing spanning tree bridge modes using CLI while WebView Spanning Tree menu has already
loaded, the menu might not correspond to the correct mode even though when refreshing the home page
the correct mode is displayed.
Workaround: Click on the Spanning Tree icon at the Outlook-like-bar located the left of the screen to
refresh the menu to the current mode.
PR 84618
On Policy > Policy > Ports Modify window, whenever trying to make a change it returns the error
message, "Port enable/disable is not supported.
Workaround: Manually set "Enabled" field to a blank during modification and continue with the rest of
the changes.
PR 84626
WebView's Adjacencies icon has non-consistent background color.
Workaround: This is a Display Issue only.
PR 84634
The WebView System File and Local Installation Management help pages for OS6600 switches docu-
ment an Update feature.
Workaround: Please ignore. The update is only available for OS7000/8800.
PR 84635
WebView may sort some numerical columns incorrectly. For example, the HRE tables and sorting by the
firmware revision.
Workaround: There is no known workaround at this time.
PR 84663
On the OS6600, the WebView IP EMP Routes page has no help page.
Workaround: There is no known workaround at this time.