User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 43
PR 84269
There are multiple bad hypertext links in the WebView help pages for Ethernet Accounting Output Statis-
tics and Ethernet Accounting Input Statistics, whereby links will incorrectly take you from one help page
to the other.
Workaround: None.
PR 84270
Webview’s UDP Relay Association page only allows a maximum of 3 entries on an OS7000.
Workaround: All services are displayed via CLI.
PR 84281
WebView's sort button may disappear on longer pages.
Workaround: There is no known workaround at this time.
PR 84338
Out-of-range value for "Session ID" such as 9999999999, a new entry is successfully created with the
upper boundary number (2147483647) instead of retaining the out-of-range entered value and displaying
an out-of-range error.
Workaround: Please enter a value within the correct range to avoid this problem.
PR 84416
On the OS7000, the "Addressless IP" section in the WebView OSPF Area Interfaces help page needs to be
removed since there is no such field.
Workaround: Ignore the field.
PR 84423
In WebView, on the Physical > Ethernet > Interface Configuration > General Modify Slot window, the
Runt Size boundary is 0 - 6 bytes instead of 0 - 64 bytes.
Workaround: Use the Modify Multiple, select entire slot (use <Ctrl> or <Shift> key), and change Runt
Size.
PR 84438
The main WebView help page does not list the Adjacencies feature in the Physical Group, the Port Secu-
rity feature in the Layer 2 Group, or the Port-Based NAC feature in the Security Group.
Workaround: There is no known workaround at this time.