User guide

Open Problem Reports and Feature Exceptions
page 40 OmniSwitch 6600/7000/8800—Release 5.1.5.R04
PR 82309
On the OS7000, the virtual ospf interface status is not displayed in WebView.
Workaround: Use the CLI show ip ospf virtual-link command.
PR 82540
On the OS7000, in the WebView help page for VRRP Tracking there is no hypertext link for Admin
Status and the Entity Type and Oper Status hypertext links and information sections need to be deleted.
Workaround: There is no known workaround at this time.
PR 82634
On an OS8800 chassis, WebView's Power Supply information page shows incorrect slot information.
Workaround: There is no known workaround at this time.
PR 82864
WebView > Physical > Ethernet > Interface Configuration > General modify page might not show the "Set
Successful" message in Netscape 7.1.
Workaround: Ignore; whenever there is an error message, the modify page stays open automatically.
PR 82912
The WebView help main page does not necessarily display the correct chassis.
Workaround: There is no known workaround at this time.
PR 83005
WebView adjacencies shows multiple connections when a your link is a aggregate.
Workaround: There is no known workaround at this time.
PR 83131
During the phase of the Mutilate DoS script attack, the show http CLI command will cause the CLI
console to hang. The CLI console will resume working once the attack is finished.
Workaround: There is no known workaround at this time.
PR 83402
On the OS7000, the title for the VRRP Delay help page says VRRP Global Parameters instead of VRRP
Delay.
Workaround: There is no known workaround at this time.