Open Problem Reports and Feature Exceptions
page 36 OmniSwitch 6600/7000/8800—Release 5.1.5.R04
PR 76783
When one clicks on the column header of a table with the SHIFT key held down, an empty browser
window is opened up. This is because column headers are functionally HTML links, and the programmed
browser behavior is to open up a link in a new browser window when the SHIFT key is held down.
Workaround: Don't hold down the SHIFT key when clicking on the column header.
PR 76949
With WebView, if you try to create an action for minimum bandwidth no error is generated.
Workaround: There is a warming message when action with min. bandwidth created from "Add QoS
Action" screen, but not from "Add Action" screen on OS7000/8800.
PR 77106
User is randomly unable to relogin to Webview on Netscape 4.7x.
Workaround: Close browser and open a new window.
PR 77279
On the OS6000 in WebView Physical - Health - LED Status, information is incorrect in the table. There
should not be two columns for the same module. The Physical Name contains unuseful data. The Primary
CMM should say "Green On", the Temperature and the Fan should say "Green(OK)"
Workaround: Ignore the extra column and the Physical Name row. Use CLI for correct status of Primary/
Secondary CMM, Temperature, and Fan.
PR 77528
On the OS6600/7000, LDAP Server entries on WebView show up with Authentication type 'None' instead
of 'Simple Password' when configured from CLI with a user ID and password.
Workaround: Change the authentication to 'simple password' type on WebView when using a userID
with Password.
PR 77638
On the OS7000, when running 'copy flash synchro' from WebView while the working and certified direc-
tories are not syncronized, Webview will report a successful operation even though it will show that it
failed on the console.
Workaround: Make sure the working directory and certified directory is synchronized before running
flash synchro.