Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 35
PR 68687
It is possible to see the ARP table empty in WebView, even though there are static routes.
Workaround: Click on the "Next" arrow found under the table. If this arrow appears under the table, this
is un indication that there are static routes, but they might be on the next page.
PR 71023
For Security -> ASA -> End-User configuration, one may add ports that are not there.
Workaround: The maximum number of ports per slot are: 24 for OS7000/8800, and 52 for OS6624/
6648.
PR 71434
When viewing files in System-SystemMgt-Install-ViewWorkingDir before acknowledging the security
certificate, a Java error will occur on an OS6600.
Workaround: In this WebView path, wait for and acknowledge the security certificate before opening
any popup windows.
PR 71484
On the OS7000, the Webview configuration dialog windows appear too low on the screen at resolutions
less than 800x600.
Workaround: None. The least resolution that the Webview Configuration Manager supports comfortably
is 800x600. While most browsers enforce bounds for new window pop-up browser windows so that they
remain visible, graphics cards set at lower than recommended resolutions will result in poor browsing
performance.
PR 71891
When adding an accept action on the OS7000 using the Actions > ACL page, if no SLB cluster is
provided, the just added action will not show up on the Actions > ACL table. (However, it will be
displayed in the Actions > All table.)
Workaround: Go to the Actions > All table.
PR 75312
If an external authentication server has a user name that's spelled exactly like another user that's local on
the switch, the option link will still appear even though the switch authenticated through the external
server.
Workaround: Use different user names.