User guide
Open Problem Reports and Feature Exceptions
page 32 OmniSwitch 6600/7000/8800—Release 5.1.5.R04
Web-Based Management (WebView)
Feature Exceptions
• WebView uses signed applets for the automatic IP reconfiguration. Those applets are signed using
VeriSign Certificates that expire every year. The certificate used for Internet Explorer and Netscape
expires every August. WebView users have to validate a warning indicating that the certificate used by
the applet has expired.
Problem Reports
PR 53599
WebView session logout does not close a TCP port on the OS7000. The port stays in established state until
the web browser is closed and restarted. A session timeout, a WebView logout, or a closure of the browser
session does not cause the remote ports to close.
Workaround: Close the web browser and restart it.
PR 55346
Java Virtual Machine needs to be installed in order to use WebView for use of Java Applets in pages such
as Health Home on the OS7000.
Workaround: If the Java Virtual Machine was not installed along with the browser, please install.
PR 56179
After a switch software update, sometimes WebView starts throwing javascript errors on the OS7000.
Workaround: Always clear the browser's cache, before trying the newer version of WebView.
PR 57944
A warning box appears on the Netscape browser when trying to telnet using HP-UX 11.0 or Sun Solaris’
on the OS7000. This is due to missing or invalid telnet settings on the applications used by the browser.
Workaround: Update your telnet settings per the instructions below:
1 Click on the "Edit Menu" on the Netscape Browser and select "Preferences".
2 Select "Navigator" on the "Category" list located to the left of the "Preferences" dialog box.
3 If the "Navigator" category doesn't show subcategories (arrowhead to the left of the "Navigator" label
is pointing to the right), then click on the arrowhead to extend the category (now the arrowhead will point
downwards).
4 Select the "Applications" sub-category.
5 Look for the 'telnet' entry (under the Description column).
6 If there is none, click on the "New..." button below the select box, or select the 'telnet' entry and click
on the "Edit..." button.