User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 29
PR 58437
A number or other variable value i.e. <num><string> will be erased if it is tabbed over on the OS7000.
Workaround: Do not "Tab" over entered variables.
PR 60688
The debug bridge hash-bitmask command displays incorrect help description such as "<slot/port>"
instead of "<slot/slice>" on the OS7000.
Workaround: There is no known workaround at this time.
PR 69058
The admin down CLI command on an OS7-GNI-U2 or OS6-GNI-U2 port does not bring the link down
on the remote end.
Workaround: Unplug the port.
PR 71993
The show fabric command will not work on Secondary CMM and will return an error message.
Workaround: There is no known workaround at this time.
PR 77445
The write terminal and show configuration snapshot output may be lost when using Windows 2000
telnet to connect to the switch.
Workaround: Use Unix, Windows NT, or Windows XP to connect to switch.
PR 80061
On the OS8800, error message "+++ [CLISHELL 22] Error on setting tty options at password (851971)"
is displayed on the console during DoS attacks. The functionality of the switch is not affected.
Workaround: There is no known workaround at this time.
PR 83127
A DoS attack on port 23(Telnet) results in the message "[CLISHELL 32] Error on setting tty options at
password(851971)” on an OS7000.
Workaround: Issue is cosmetic and doesn't effect performance of the switch.