Open Problem Reports and Feature Exceptions
page 112
PR 79957
It is found that under 13 hours of stressed traffic test with PAUSE flow control on 10G, less than 100
PAUSE frames were seen with CRC error, none on data frame. Broadcom has been notified but they have
not been able to provide any answer. However, this should not be an issue as the default PAUSE setting is
OFF and the rate of corruption is extremely low (<100 out of 23 millions PAUSE frames).
Workaround: Do not turn on PAUSE flow control in 10G.
PR 79958
It is found that after a CLI command issuing an ADMIN DOWN to a 10G link, a few corrupted packets
are seen on the remote station. This is believed to be a side effect of Xenpak which chop off the packet
abruptly when the Rx and Tx link is disabled. However, this happens only under very heavy traffic.
Workaround: There is no known workaround at this time.
PR 80442
Error message “No Such Object available on this agent” returned for 10G specific tables. This problem
only occurs with SNMP walk application.
Workaround: There is no known workaround at this time.
PR 81010
OS8-GNI-C-24 may encounter some packet loss for a small size packets if it is wired traffic (100% traffic
inflow).
Workaround: This is an oversubscription condition. Lower the incoming traffic rate.
PR 81489
The BCM 5632 can hang while waiting for EEPROM config download during boot up. The 10G interface
will never come up if this situation occurs.
Workaround: Power the NI module off and then on again.
PR 81727
Unable to set primary Xenpak from WebView or OmniVista.
Workaround: Use CLI command.
PR 83062
The 10G interface may not come up upon initial boot up while traffic is running. It may be due to insuffi-
cient internal IPC resource.
Workaround: Plug the fiber in after the switch boot up or NI hot swap.