PR 61916
Fast Ethernet ports not able to auto detect speed and duplex setting with some cards. Seen with Dolch
sniffer.
Workaround: Manually configure the speed and duplex settings.
PR 65197
The qos default queues command may cause the NI to have a different configuration than the CMM.
Workaround: The qos default queues <num> command requires a reset of the NI before it takes affect.
One can reset the NI by doing a no power ni <num> then power ni <num> or do a reload working no
roll-back to have the setting take effect.
PR 69099
Pause frames cannot be generated by the MAC when oversubscribing a single port.
Workaround: There is no known workaround at this time.
PR 71106
Using Xircom CreditCard Ethernet 10/100 + Modem 56, if the speed and duplex of both the OS7-ENI-
C24 switch and the NIC are fixed to 100FD, then no link is detected.
If auto-negotiation is enabled on the switch the connection is only detected as 100HD, even though the
NIC is configured to 100FD.
Workaround: By using auto-negotiation, a link can be detected, although this will only be 100HD and
not 100FD.
PR 71593
Avaya Cajun P333R has connectivity issues when connected to the OS7000.
Workaround: There is no known workaround at this time.
PR 77702
A four-port NetGear Hub gives an uneven number of preamble bytes that will be dropped.
Workaround: Use the 8-port Hub NetGear DS108.