PR 82675
If the boot flag is set to 0x40000, then it will cause the tssApp task to crash when attempting to execute
some CLI commands on an OS7000 or OS6600.
Workaround: Make sure boot flag is set to 0.
PR 83669
Chassis will not be able to bootup when the boot flag is set to 0xb8000 on an OS7000.
Workaround: Do not set the boot flag to 0xb8000.
PR 84453
On an OS6600, Chassis Supervision does not know if the configuration on the NI side has been modified
and then to reload the corresponding NI in case of a takeover with unsaved configs.
Workaround: Reboot the stack.
PR 84469
OS6600 system rebooted with dump file while certifying image.
Workaround: There is no known workaround at this time.
PR 84483
On the OS7000, at the end of the actual fpga driver downloading, there is a short period of wait before the
whole update process is declared ended.
Workaround: There is no known workaround at this time.
PR 85230
On the OS7000, when a user does not follow the steps of the automated fpga update procedure and repeat-
edly issues the fpga update command, the update may be completed correctly.
Workaround: Following the formal fpga update procedure recommended in the user's manual, users will
not encounter this problem.