Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 105
PR 76658
MAC Server manager a range of max 256 MACs. If the OS7000 is configured with a MAC range exceed-
ing 256 MACs, MAC server will not be consistent. The MAC range eeprom CLI command rejects the
command if the MAC count exceeds 256.
Workaround: Reconfigure the MAC-range eeprom to be 256 MACs or less
PR 77208
If the system watch dog times out on an OS6624/6648, the console may hang after reboot on the primary
switch and rebooted again.
Workaround: There is no known workaround. The system will reboot and recover itself.
PR 79104
On the OS6600, when using Webview, if the configuration is changed and a write memory performed,
webview is unable to determine that a certify is required (copying the change from working to certified).
Workaround: After performing the write memory action, click refresh on webview page. Then copy
working to certified from webview is successful.
PR 79859
Firmware reversion is not shown using SNMP on the OS7000.
Workaround: There is no known workaround at this time.
PR 80937
IPC buffers can be used up by VLAN Manager on an OS8800 when a bootup or CMM takeover occurs.
Workaround: There is no known workaround at this time.
PR 82090
On the OS7000, while ftp'ing in the miniboot, transfer may stop after which no IP traffic of any kind will
be returned.
Workaround: Reboot back into the miniboot and finish transferring the files.
PR 82635
On the OS7000, there is no SNMP MIB support to display number and status of fan modules on a switch
via SNMP MIB Browsers and WebView. The number and status of fans can be displayed only via the CLI
interface's command: show fan.
Workaround: There is no known workaround at this time.