PR 66815
If the working directory is in upper case "WORKING" (normally will happen if it is created on a PC), then
the install command from either CLI or WebView will remove Hrelease.img from the working directory
getting removed on an OS6624/6648.
Workaround: Rename the upper case "WORKING" directory to a lower case "working" directory. Do
not use rename WORKING working (this will not work). Rename WORKING to something else first
and then rename it back to lower case "working". For example:
rename WORKING ttt
rename ttt working
PR 67104
During the system bootup sequence, the memory size may not be display the correct value (i.e., 64 or 128
MB) on an OS6624/6648. This is only a cosmetic problem.
Workaround: Ignore the memory size during bootup.
PR 67889
Ixia Scriptmate automates auto-negotiation test. Hence the timing for enabling port (PHY and MAC)
between Ixia and the OS8800 is different. Since the OS8800 does not accumulate statistics before the port
is enabled, there is a chance to have statistics mismatch between Ixia and the switch.
Workaround: There is no known workaround at this time.
PR 68266
The show module command will not work on the OS8800 if the console of one of the 2 CMMs is config-
ured as the modem port with modemControlOn.
Workaround: There is no known workaround at this time.
PR 68275
An unknown destination address, under heavy traffic, may exceed the threshold defined for broadcast traf-
fic on an OS6624/6648.
Workaround: There is no known workaround at this time.
PR 68661
Next error message may appear at startup: sync 93: Accept failed [estatus = CS_CSM_INrrno 5] on an
OS6624/6648.
Workaround: There is no known workaround at this time.