User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.5.R04 page 101
PR 62067
Port link may toggle if using a Media Converter (100BASE-TX to 100BASE-FX) on the OS7000.
Workaround: There is no known workaround at this time.
PR 62628
The ASIC version number is missing from its field when a show module long command is issued.
Workaround: There is no known workaround at this time. It is a display issue only.
PR 63605
Some Fweb* images show up in the "loaded m-code" table before the OS7000 reloads.
Workaround: When a switch comes up, the only file that WebView loads is the web.lnk file from
Fweb.img. If there is no web access to the switch, nothing else is loaded. When a user accesses a certain
page, the system will dynamically load the necessary file. The WebView image/s that show up in the show
microcode loaded output is dependent upon what pages were accessed. Therefore these images can vary
from switch to switch and from time to time.
PR 63661
The message “KERNAL reboots!” may display when changing system time on the OS7000.
Workaround: If you want to change the system time, do not execute the debug command debug chassis
auto-reboot disable prior to doing so or your system will reboot.
PR 65248
When the user configures the EMP IP address to "." or 0.0.0.0 in an attempt to clear the address on the
OS7000, it will in fact add it as the default route (0.0.0.0).
Workaround: There is no known workaround at this time.
PR 66781
The Operating System does not support non-contiguous MAC ranges on the OmniSwitch 8800.
Workaround: There is no known workaround at this time.