User guide

Open Problem Reports and Feature Exceptions
page 100 OmniSwitch 6600/7000/8800—Release 5.1.5.R04
PR 59510
The time for 10/100 ports to auto-negotiate is dependent upon the number of such ports configured in the
OS7000 system. The more ports configured for auto-negotiation, the longer it will take before they all
auto-negotiate. This is observed only at bootup.
Workaround: There is no known workaround at this time.
PR 60599
The watch dog will not reboot the switch when the OS7000 locks up due to a corrupted image file.
Workaround: Power cycle the switch and FTP a new version of the software if possible.
PR 60636
Fully qualified instances in "systemMicrocodeDependencyTable", return a NoSuchInstance error on the
OS7000. Only SNMP GetNext requests work on the entire table, but SNMP get for specific instances fail.
Workaround: User must use snmpget on table to read items.
PR 60675
The MAC-range command will not update the routing information upon completion on the OS7000.
Workaround: For a MAC-range command to take effect (have the chassis use the new MACs), the chas-
sis will need to be rebooted. In fact, once you change the first MAC-range you MUST reboot, all VLAN
and routing functionality after that point will not be supported.
PR 61018
While modifying the boot parameters on the OS7000, an input of “.” for an IP address is interpreted as an
IP address of 0.0.0.0.
Workaround: There is no known workaround.
PR 61534
The FTP session will have problems connecting to the OS7000 while the certify process is still running.
Workaround: Do not attempt to FTP files to/from switch while certify process is still running.
PR 61572
When the protocol reference is not specified in the ethernet frame, layer2 traffic is not accepted on the
OS7000.
Workaround: There is no known workaround at this time.