Specifications
March 2005 Completing a Stacked Configuration 27
Connecting Cables
to Stacking Modules
Guidelines
• If you have not already individually assigned slot
numbers and powered off each switch, do not connect
stacking cables to the stacking modules. Instead, refer to
“Assigning Slot Numbers” on page 25 and follow the
instructions for assigning slot numbers to each switch.
• Before attempting to connect OmniSwitch 6600 Family
switches in a stacked configuration, be sure that stacking
modules are installed in the EXPANSION/STACKING
slots of all switches. The stacking module provides two
dedicated High Speed Serial Data Connectors (HSSDCs) at
ports 27 and 28 (OS6624, OS6600-U24, OS6600-P24,
OS6602-24) or 51 and 52 (OS6648 and OS6602-48). For
detailed information on installing stacking modules, refer
to “Installing Uplink and Stacking Modules” on page 16.
• Stacking modules can only be installed in the far-right
module slot. This slot is labeled EXPANSION/STACK-
ING and contains port positions 27 and 28 (OS6624 and
6600-U24) or 51 and 52 (OS6648).
• Do not attempt to install the stacking module at the
EXPANSION slot at port positions 25 and 26 (OS6624,
OS6600-U24, OS6600-P24, OS6602-24) or 49 and 50
(OS6648 and OS6602-48).
• Port numbers are clearly marked on the chassis front
panel.
1 Starting from the top of the stack, attach one end of a
30 cm stacking cable to a High Speed Serial Data
Connector (HSSDC) located on the switch’s stacking
module, as shown.
EXPANSION/STACKING
51
52
LINK/ACT
LINK/ACT
Attaching the Stacking Cable to a Stacking Module