User guide

Configuring Virtual Chassis Configuring Virtual Chassis
page 13-22 OmniSwitch AOS Release 8 Switch Management Guide May 2014
Additional EMP IP Addresses
An additional CMM IP address, stored in NVRAM can also be configured. These addresses can be used to
access a specific CMM but are not required for remote access. On an OmniSwitch the IP addresses are
named as follows and are associated to each CMM on each chassis.
EMP-CMMA-CHAS1
A direct connection to the associated CMM’s console port is required before attempting to change IP
address information using the modify boot parameters command as shown in the example below:
-> modify boot parameters
Boot > boot empipaddr 255.255.100.50
Boot > boot empmasklength 16
Boot > commit system
Boot > commit
Controlled Shutdown of a Virtual Chassis Participant Switch
The virtual-chassis shutdown command allows a switch to be brought to an isolated state where all user
ports and virtual-fabric link member ports are brought down. This allows for the graceful removal of the
switch from the active virtual chassis topology.
Note: This command should not be used on the Master chassis.
EMP-CHAS1
10.255.100.1
EMP-CHAS2
10.255.100.2
EMP-VC
10.255.100.100