User guide
Virtual Chassis Split Protection (VCSP) Configuring Virtual Chassis
page 13-14 OmniSwitch AOS Release 8 Switch Management Guide May 2014
Use the virtual-chassis split-protection guard-timer and the virtual-chassis split-protection admin-
state commands to configure the guard timer and enable/disable VCSP.
Automatic Recovery
If the VFL link recovers and the sub-VC reconnects to the active VC the sub-VC will automatically
reboot. The protection units will come up in the protection state; however they will now be part of the
active VC but their front panel ports will still be disabled. The master of the combined VC will detect that
there are new elements in the protection state. The master will wait for 60 seconds then bring one element
at a time from the protection state until all elements are active.
Once complete, the master will generate a trap indicating the VC has been recovered.
VC Split Example
1. VC split detected, sub-VC transitions to PROTECTION state.
2. Sub-VC front panel ports shutdown to avoid duplicate
addresses on network
3. PROTECTION PDUs sent by sub-VC to active-VC over helper linkagg.
1
Normal Opera-
tion
VCSP PDUs sent over helper linkagg and relayed by
helper switch.
2
VC Split
Sub-VC
Active-VC
3
Recovery
1. VFL link recovers, new elements detected by Master.
2. Manual Recovery - Administrator disables/enables VCSP to clear PROTECTION state.
3. Automatic Recovery - After guard-timer expiration, Master will bring up elements one at a time.
4. Once VC is functioning, Master will send trap indicating VC recovery.