Specifications
August 2011 Your First Login Session 13
More Information On User Accounts. A user account
includes a login name, password, and user privileges.
Privileges determine whether the user has read or write
access to the switch and which commands the user is
authorized to execute. For detailed information on setting
up and modifying user accounts, refer to the OmniSwitch
AOS Release 7 Switch Management Guide
Setting IP Address Information for
the EMP
The Ethernet Management Port (EMP) is located on the CMM
module. The EMP allows you to bypass the Network Interface
(NI) modules and manage the switch over the network directly
through the CMM.
To connect to the switch through the EMP Ethernet connection
use the default address below or change the port’s IP address if
desired.
Note. You should be connected to the switch via the
console port before attempting to change IP address
information.
To change the default IP and mask, use the
ip interface command. For example:
-> ip interface emp address 168.22.2.120 mask
255.255.255.0
Verify your settings using the show ip interface command.
See the OmniSwitch AOS Release 7 Switch Management
Guide for additional information regarding EMP port
addressing.
Note. Although you have configured the EMP with valid
IP address information, you will not be able to access the
switch through this port (i.e. TELNET, FTP, HTTP, SSH
or SNMP) until you have unlocked these remote session
types. See “Unlocking Session Types” on page 14 for
more information.
Default EMP IP Address 10.255.24.81
Default EMP Mask 255.0.0.0