Show Currently Used Configuration
In a chassis with a redundant CMMs, the display for the currently running configuration tells the user if
the primary and secondary CMMs are synchronized.
To check the directory from where the switch is currently running and if the primary and secondary
CMMs are synchronized, enter the following command on a stack:
-> show running-directory
CONFIGURATION STATUS
Running CMM : PRIMARY,
CMM Mode : DUAL CMMs,
Current CMM Slot : 1,
Running configuration : WORKING,
Certify/Restore Status : CERTIFY NEEDED
SYNCHRONIZATION STATUS
Flash Between CMMs : SYNCHRONIZED,
Running Configuration : NOT AVAILABLE,
The show running-directory command is described in detail in the OmniSwitch AOS Release 7 CLI