User guide
SNMP Traps Table
OmniSwitch AOS Release 7 Switch Management Guide March 2015 page B-17
62 alaErpRingStateChanged alaErpRingId
alaErpRingState
erp This trap is sent when the ERP
Ring State has changed from
“Idle” to “Protection”.
alaErpRingId—The unique Ring identifier.
alaErpRingState—The current state of the Ring (0=Idle, 1=Protection).
63 alaErpRingMultipleRpl alaErpRingId erp This trap is sent when multiple
RPLs are detected in the Ring.
alaErpRingId—The unique Ring identifier.
64 alaErpRingRemoved alaErpRingId erp This trap is sent when the Ring is
removed dynamically.
alaErpRingId—The unique Ring identifier.
65 ntpMaxAssociation ntp This trap is generated when the
the maximum number of peer
and client associations config-
ured for the switch is exceeded.
NtpMaxAssociation—The maximum number of peer and client associations that the switch will serve.
66 ddmTemperatureThresholdViolated ifIndex
ddmNotifica-
tionType
ddmTempera-
ture
This trap is sent when an SFP/
XFP/SFP+ temperature has
crossed any threshold or
reverted from previous threshold
violation for a port represented
by ifIndex. It also provides the
current realtime value of SFP/
XFP/SFP+ temperature.
ifIndex—The interface index.
ddmNotificationType—The trap type for monitored DDM parameters (clearViolation(1), highAlarm(2), high-
Warning(3), lowWarning(4), lowAlarm(5).
ddmTemperature—The temperature, in tenths of a degree celcius.
67 ddmVoltageThresholdViolated ifIndex
ddmNotifica-
tionType
ddmSupplyVolt-
age
port This trap is sent when SFP/XFP/
SFP+ supply voltage has crossed
any threshold or reverted from
previous threshold violation for a
port represented by ifIndex. It
also provides the current realtime
value of SFP/XFP/SFP+ supply
voltage.
ifIndex—The interface index.
ddmNotificationType—The trap type for monitored DDM parameters (clearViolation(1), highAlarm(2), high-
Warning(3), lowWarning(4), lowAlarm(5)
ddmSupplyVoltage—The voltage, in tenths of a volt.
68 ddmCurrentThresholdViolated ifIndex,
ddmNotifica-
tionType
ddmTxBiasCur-
rent
port This trap is sent when if an SFP/
XFP/SFP+ Tx bias current has
crossed any threshold or reverted
from previous threshold violation
for a port represented by ifIndex.
It also provides the current real-
time value of SFP/XFP/SFP+ Tx
bias current.
No. Trap Name Objects Family Description