User guide

Upgrading the Software Getting Started and Upgrading AOS
page 1-10 OmniSwitch AOS Release 7 Switch Management Guide March 2015
Resetting NIs - OS10K
After performing an ISSU upgrade the NIs must be reset to complete the ISSU upgrade. They can be reset
manually using the ‘issu slot’ or ‘reload slot’commands. If the NIs are not reset by the time the NI reset
timer expires (Refer to “Getting Started Specifications” on page 1-2), they will be reset individually by the
system in ascending order beginning with slot 1. Once the reset NI reaches a ready state, the next one is
reset. This process continues until all NIs have been reset.
Staggered Software Upgrade
This section describes the basic steps for upgrading an OmniSwitch standalone or virtual chassis using the
staggered upgrade procedure. This section is an overview. For specific step-by-step instructions please
refer to the Release Notes.
1 Follow the instructions in the Switch Maintenance” on page 1-8 section
2 Download the upgrade files
3 Create a directory to hold the upgrade files on the Master chassis
4 FTP the upgrade files and the script file to the upgrade directory on the Master chassis.
5 Execute the script on the Master chassis:
6 Verify the software upgrade
7 Certify the software upgrade