Datasheet
www.alcatel-lucent.com Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo
are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility
for inaccuracies contained herein. Copyright © 2009 Alcatel-Lucent. All rights reserved.
EPG3310090901 (10)
Technical specifications
Radio specifications
• DECT/GAP
• Frequency band:
¬ 1.88 GHz to 1.90 GHz (Europe)
¬ 1.91 GHz to 1.93 GHz (South
America)
¬ 1.92 GHz to 1.93 GHz (US)
¬ 1.90 GHz to 1.92 GHz (Asia)
Note: ATEX version available for
Europe only
• Channels can be disabled by call
server to adapt to local regulations
• Channel bandwidth: 1.728 MHz
• Transmission carriers: 10
• Number of simultaneous active
time slots: six max
• RF power 250 mW, limited to
100 mW for US (DECT 6.0)
• Radio coverage from 50 m to
300 m (approx 55 yd to 328 yd)
depending on location and
environment
• Switched antenna diversity
• Integrated omnidirectional
antenna 3 dBi gain (maximum)
• SMA connectors for connecting
external antennas
• SAR: less than 0.25 W/kg for six
simultaneous active calls
Protocol specifications
• ETSI GAP-compliant
• Supports identity, authentication
and encryption
• Software downloading from
call server
Electrical interface
• 1 or 2 TDM UA interface
• Twisted pair cabling remote
feeding up to 1200 m/approx.
1312 yd
Power feeding
• Remote power feeding on TDM
link. Typical consumption for six
simultaneous calls: 2 W
• Local power feeding for extended
wiring range to call server
(indoor version)
• Uses same power supply as
Alcatel-Lucent fixed wired
phones (48 V)
Environmental
Environmental
• IEC 721-3-1 Storage
• IEC 721-3-2 Transport
• IEC 721-3-3 Stationary
• IEC 721-3-7 no Stationary
Operating temperature
• Indoor: +10°C to +40°C
(+50°F to +104°F)
• Outdoor, ATEX: -20°C to +55°C
(approx. -4°F to +131°F)
IP class
• Indoor base station: IP 20
• Outdoor base station: IP 55
• ATEX base station: IP 65
Physical specifications
• Wall-mountable
• Indoor
¬ Height: 8.5 in. (215 mm)
¬ Width: 6.7 in. (170 mm)
¬ Depth: 1.8 in. (45 mm)
¬ Weight: 15.5 oz (440 g)
• Outdoor
¬ Height: 14.4 in. (365 mm)
¬ Width: 8.3 in. (210 mm)
¬ Depth: 2.6 in. (65 mm)
¬ Weight: 52.2 oz (1.48 kg)
•ATEX
¬ Height: 29.92 in. (760 mm)
¬ Width: 11.81 in. (300 mm)
¬ Depth: 5.90 in. (150 mm)
¬ Weight: 359.8 oz (10.2 kg)
Regulatory
EC Directive
• 1999/5/EC (R&TTE)
• 94/9/EC (ATEX)
Safety
• IEC 60950-1
• EN 60950-1
• UL 60950-1*
• CAN/CSA-22.2 No 60950-1*
* For indoor and outdoor base
stations only
EMC and radio
• EN 301406 DECT RF
• EN 301489-06 EMC
• FCC CFR47 Part 15D US Code
of Federal Regulations SAR*
* For indoor and outdoor base
stations only
SAR
• EN 50385 Human exposure
• FCC OET Bulletin 65 supplement
C US Human exposure*
* For indoor and outdoor base
stations only
DECT
• EN 300 175 DECT CI
• EN 301 406 (TBR6) DECT RF
• TBR10 Telephony
• TBR22 GAP
ATEX classification
• II 2 G EEx de IIC T6
ATEX standards
• EN 60079-0 general
requirements
• EN 60079-1 Fameproof
enclosures “d”
• EN 60079-7 equipment protection
by increased safety “e”