User guide
OmniPCX Enterprise / OmniPCX Office
TECHNICAL RELEASE NOTE OF VoWLAN
R4.2.1
TC1308 12 Ed. 01 / 03 March 2010
pd14cno.bin
pd14odno.bin
pd14shim.bin
pd14udno.bin
pi1400no.bin
slnk_cfg.cfg
miptr3bin
• Use of the OmniPCX internal TFTP server is recommended for the mass deployment.
In dynamic mode, the TFTP server management is generally done through the management
of lanpbx-mipt.cfg file. Then the MIPT binaries files must be placed on the call server
hard disk, under /DHS3bin/downbin/wifi directory
(‘owner/group’ rights are 2011 1002 for all files).
To take in account the version, the Reset for Update can be activated for all
handsets to upgrade
and the 120.023 deployment can be done with the OmniPCX TFTP server.
5.3.2 Upgrade to 120.023 on OmniPCX Office
The binary files of software version 120.023 and the HAT application can be found on the BPWS in
section Technical Support > Software download > Phones > IP Touch WLAN.
To ensure the compatibility of the new 120.023 MIPT version with the existing VoWLAN topology
onsite, the following steps are recommended:
When the IP Touch WLAN Handset starts, it compares its current version with the software available
on the TFTP server. If it is a different software version, it will be updated automatically:
• By external TFTP Server on the LAN:
Put the SW in an external TFTP Server available on the LAN. Its IP address must be configured
in the TFTP Server IP field available from the administration menu of the handset.
or
• By Handset Administration Tool (without TFTP Server):
The HAT tool permits to update the IP Touch 310/610 WLAN Handset’s version. In that case,
255.255.255.255 must be configured in the TFTP Server IP field available from the
administration menu of the handset in order to avoid update request to another TFTP Server.
5.3.3 MIPT downgrade cases
For all VoWLAN topologies installed with OAW release 3.4 and 120.023 MIPT version which need to
be downgraded to pre-120.023, it must be done first intervention on OAW and MIPT to
recover the WMM-PS QoS.
• Deactivate the update of binaries for the Mipts sets.
• The ACM (Admission Control Mandatory used for call control traffic) must be set to 0. See
technical communication TC1315 Example of OAW Configuration in reference.
• Manage the QoS WMM-AC to Optional into the set.