Specifications
ENT_MLE_015989 - Ed 02_2014-10-13
Chapter 13: Topology – Network Services
57/64
Alcatel-Lucent Enterprise Communication Solutions
April 2014 Offer
Connections to the OmniPCX ACT:
Two adjacent standard UA ports
Twisted-pair cable (maximum distance: 1200 meters / approx. 1,312 yards)
Remote power feed through the system or (internal power via a 230V/42V battery (150
mA)
256 IBS base stations is the maximum number handled by an Alcatel-Lucent OmniPCX
Enterprise Communication Server
Antenna
Built-in antenna
Connector for external antenna
Switched antenna diversity
Environment
Operating temperature: +10°C to +40°C (+50°F to +104°F)
Environment protection: IP 20
Wall-mountable
Number of users in the same cell
2.8 Erlang/4070 IO-two UA links can support up to 14 standard users per cell
Traffic handling based upon a standard user’s traffic estimated at 0.2 Erlangs
3.3.6.2.2 Optimized outdoor base station (4070 EO IBS outdoor)
The 4070 EO IBS outdoor is designed for outdoor use. The differences between 4070 IO IBS indoor
and 4070 EO IBS outdoor are:
Remote power feeding only through the system
External antenna
Operating temperature: -20°C to +55°C (approx. -4°F to +131°F)
Environment protection: IP 55