Installation manual
- Manual, if the terminals are not connected to a same subnet as Alcatel-Lucent OmniPCX
Office Communication Server, or if the DHCP server integrated into the
CoCPU-1/CoCPU-2 board is deactivated: in this case the IP parameters and the TFTP
server address have to be entered on the terminals.
Registering e-Reflexes terminals connected to a different subnet from the
Alcatel-Lucent OmniPCX Office Communication Server
- Connect the power to the relevant terminal.
- Press i then #.
- Press 2 (IP Parameters)
- Press 1 (Static mode)
- Press 2 (IP Address). Enter the IP address of the terminal. Validate by pressing #.
- Press 3 (Subnet Mask). Enter the IP address of the CoCPU-1/CoCPU-2 board subnet
mask. Validate by pressing #.
- Press 4 (Router Address). Enter the IP address of the external router. Validate by pressing
#.
- Press 5(TFTP Server). Enter the IP address of the CoCPU-1/CoCPU-2 board. Validate by
pressing #.
- Press 7 (id VLAN). To switch the e-Reflexes from the mode without VLAN to the mode with
VLAN (Virtual LAN), press 1 then program the VLAN value (decimal value between 0 and
4095). To deactivate the VLAN, press 1 again.
Note:
Option 6. Main CPU Address is not used).
- Press End.
- Press # to save the parameters, the terminal will display the 2 screens "Modification
saved" and "IPPhone will reset" in turn before reinitializing itself:
At startup, the e-Reflexes terminal will execute six registration phases:
- Phase 1: IP initialization
- Phase 2: Downloading of the configuration file
- Phase 3: Downloading of the binary file
- Phase 4: Flashing of the binary
- Phase 5: Downloading of the starting file
- Phase 6: Establishing of IP signaling
At the end of phase 6, the station is initialized and the terminal appears in the list of the OMC
stations.
The use of e-Reflexes terminals requires system configuration using OMC, that is:
- Number of VoIP channels subscribed.
- Activating/deactivating the DHCP server (dynamic allocation or manual input of IP
addresses).
*+