Installation manual
- PBX: use in private network with TX and RX twisted pairs.
4.2.1.1.8 LANX and LANX-1 board
RJ45 pin 1 2 3 4 5 6 7 8
Ports 1 to 15 RX+ RX- TX+ TX-
Up-Link TX+ TX- RX+ RX-
- Ports 1 to 15: internal ports.
- Up-Link: LAN connection.
4.2.1.1.9 LANX-2 board
RJ45 pin 1 2 3 4 5 6 7 8
Ports 1 to 14 RX+ RX- TX+ TX-
GE1, GE2 TR0+ TR0- TR1+ TR2+ TR2- TR1- TR3+ TR3-
- Ports 1 to 14: 10/100 BT ports.
- GE1, GE2: 10/100/1000 BT ports.
4.2.1.1.10 APA board
RJ45 pin 1 2 3 4 5 6 7 8
Output 1 ZSETB ZSETA LB-Ring LA-Tip ZB ZA
Outputs 2 to 8 LB-Ring LA-Tip
- 1 : connection of network line 1, SLI interface and callback terminal
- 2 to 8: connection of other analog trunk lines
4.2.1.1.11 DDI board
RJ45 pin 1 2 3 4 5 6 7 8
1 to 4 L- L+
- 1 to 4: connection of DDI analog trunk lines.
4.2.1.1.12 ATA Board
RJ45 pin 1 2 3 4 5 6 7 8
Outputs 1 to 4 PEA PEB
SLI outputs ZA ZB
PHONE outputs ZSETA ZSETB
4.2.1.2 TYPES OF CABLE TO USE
Chapter
4
*+
4-6