The maximum length for FE cables is 100 meters (325 feet).
When the OmniAccess OAW-AP70 is installed in an air-handling space, as
described in NEC (2002) Article 300.22 (C), POE is required. Also, any FE cable
installed in such spaces should be suitable under NEC Article 800.50 and
marked accordingly for use in plenums and air-handling spaces with regard to
smoke propagation, such as CL2-P, CL3-P, MPP or CMP.
Install cables in accordance with all applicable local regulations and practices.
Serial Breakout Adapter
The optional serial breakout adapter is used to separate the serial
communications lines from the OmniAccess OAW-AP70 FE+SPOE port. This
allows the administrator to connect a local serial console directly to the AP and
access the apboot prompt for manual provisioning.
The serial breakout adapter pin-outs are shown in Figure A-2 :