Specifications
OmniAccess Reference: AOS-W System Reference
812 Part 031652-00 May 2005
poll-retries # of retries before it is declared down
sta-ageout-interval STA ageout interval in minutes. 0 to disable
sta-inactivity-timeout STA inactivity timeout in scan seconds.
stat-update enable or disable Stat update in DB
wired-laser-beam enable or disable wired side protection
<cr>
global-policy
(switch) (wms) #global-policy ?
detect-bad-wep enable or disable detect bad/weak WEP policy
detect-interference enable or disable interference detection
interference-inc-thre.. % increase in frame retry rate or frame receiver
erro
r rate after with interference is reported
interference-inc-time.. Amount of time FRR or FRER
interference-wait-time Amount of time in seconds air monitor should
learn st
ate of link between AP and STA to create FRR and
FRER
baselines
<cr>
ids-policy
(switch) (wms) #ids-policy ?
adhoc-check IDS Adhoc Network Detection
adhoc-quiet-time Time to wait in seconds after detecting Adhoc
activit
y after which the check can be resumed
ap-flood-check IDS Fake AP Flood Detection
ap-flood-inc-time Number of consecutive seconds over which the AP
count
is more than the threshold
ap-flood-quiet-time Time to wait in seconds after detecting an AP
flood b
efore continuing the check
ap-flood-threshold The number of spurious APs in the system
dsta-check IDS Disconnect Station Analysis
dsta-quiet-time Time to wait in seconds after detecting
disconnect st
ation attack after which the check can be resumed
eap-check IDS EAP Handshake Anomaly Detection
eap-rate-quiet-time Time to wait in seconds after detecting an EAP
handsh