For final production, import color definitions from \\daldoc01\docteam\templates\framemaker\book-template\color-defs\ production-colors.fm. Do not import other template elements such as page layout. To return to the draft version, import color def’ns from draft-colors.fm. To switch to the beta version, import color def’ns from beta-colors.fm OmniAccess 5510 Unified Services Gateway Getting Started Guide Release 3.
CAUTION: THIS EQUIPMENT IS TO BE INSTALLED AND SERVICED ONLY BY QUALIFIED SERVICE PERSONNEL. Batteries Caution. There is a danger of explosion if the battery in your chassis is incorrectly replaced. Replace the battery only with the same or equivalent type of battery recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. The manufacturer’s instructions are as follows: 3 4 5 Return the module with the battery to Alcatel-Lucent.
Table of Contents Package Contents..................................................................................................................... 1 Required Tools and Equipment .......................................................................................... 2 Connecting AC Input Power...................................................................................................... 3 Connecting to the OmniAccess 5510 USG Console Port .......................................................
List of Figures Connecting the Power Brick on OmniAccess 5510 USG 3 Connecting to the OmniAccess 5510 USG Console 4 Connecting to Internal Network 16
List of Tables Console Properties 5 OmniAccess 5510 USG System LED Status 6
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) OmniAccess 5510 USG Overview OmniAccess 5510 USG Overview The OmniAccess 5510 USG is designed to provide most commonly used network services, such as routing, switching, wide area network (WAN) connectivity, network security with firewall, and related services using a non-modular platform providing Ethernet switching and WAN interface. PACKAGE CONTENTS 1.
Left running head: Chapter name (automatic) Package Contents REQUIRED TOOLS AND EQUIPMENT You need the following items to install the OmniAccess 5510 USG: • • • Note: Electrostatic Discharge Wrist Strap (ESD) Level (optional) Tape Measure (optional) This equipment is designed to the highest quality standards of materials, workmanship, and safety. Do not bypass any of the safety features of this equipment or operate this in an improper environment.
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) Connecting AC Input Power CONNECTING AC INPUT POWER This section provides the procedures for connecting AC-input power to the OmniAccess 5510 USG. Note: 1. The OmniAccess 5510 USG installation must comply with all the applicable codes. All the hardware materials used should be of compatible material and preclude loosening, deterioration, and electrochemical corrosion of hardware and joined material. 2.
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) Connecting to the OmniAccess 5510 USG Console Port CONNECTING TO THE OMNIACCESS 5510 USG CONSOLE PORT The OmniAccess 5510 USG has a RJ-45 console port connector. A DB-9 to RJ45 (female) adapter is provided with the system to access the console port via a DTE (computer/terminal) using a straight-through Ethernet cable.
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) Connecting to the OmniAccess 5510 USG Console Port Step 3: Set the console session as follows: Table 1: Console Properties Parameter Value Baud rate 9600 Parity None Data Bits 8 Stop Bit 1 Flow control None Step 4: Watch for console message output or press the Enter key to get the device prompt.
Left running head: Chapter name (automatic) Starting the OmniAccess 5510 USG STARTING THE OMNIACCESS 5510 USG After installing OmniAccess 5510 USG and connecting cables, follow the procedure given below to start the system: Step 1: Before you power ON the OmniAccess 5510 USG, check the following: • Ensure that the power supply chassis connector is securely inserted into the chassis and secured. • Ensure that a PC or VT100 terminal is connected to the console port, using the appropriate console cable.
Left running head: Chapter name (automatic) Starting the OmniAccess 5510 USG OmniAccess 5510 USG Bootup Message Example: The following is an example of the bootup message on an OmniAccess 5510-TE USG: U-Boot 1.1.3 (Rev 2.5) (Mar 4 2010 - 16:14:03) OmniAccess 5510 Press Ctrl-C for Boot Options : 0 Loading system Images...
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) Starting the OmniAccess 5510 USG Loading Startup Config ... No Startup Config Loading Factory Default Config ... /-------- Percent Complete -------- Username : The following is an example of the bootup message on an OmniAccess 5510 AB USG (ADSL Annex B): U-Boot 1.1.3 (Rev 2.5) (Mar 4 2010 - 16:14:03) OmniAccess 5510 Press Ctrl-C for Boot Options : 0 Loading system Images...
Left running head: Chapter name (automatic) Performing Basic Configuration Tasks PERFORMING BASIC CONFIGURATION TASKS Once you boot OmniAccess 5510 USG and connect to the console, you can start configuring your OmniAccess 5510 USG either through the Command Line Interface (CLI) or the web-based Graphical User Interface (GUI). ACCESSING THE OMNIACCESS 5510 USG THROUGH CLI The CLI is the primary interface to access the OmniAccess 5510 USG through the console.
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) Performing Basic Configuration Tasks On OmniAccess 5510-AA/AB USG: • • HTTPS, SSH, and TR-069 access to the system is enabled. • SNMP v2 along with related parameters like community string, user name, password is enabled. • • • All interfaces will be in administratively ‘UP’ state. • • • VLAN 1 will have default IP address 192.168.1.1 • ATM sub-interface comes up with VPI/VCI value as 0/32.
Left running head: Chapter name (automatic) Performing Basic Configuration Tasks ! ! ! Clock Timezone ! clock timezone utc ! ! CWMP Configuration ! ! ! CWMP Configuration (End) ! ! ! SNMP Configurations ! snmp agent rocommunity aluro ! aaa services ! username admin password 5 21232f297a57a5a743894a0e4a801fc3 username recovery password 5 e35dfd3c8ba8a900381051844a603a6e username superadmin password 5 8ec760e45da5b29afb19ed8d68a3eb5e enable password 5 21232f297a57a5a743894a0e4a801fc3 ! ! ! ! aaa authorizatio
Left running head: Chapter name (automatic) top ! interface Serial0 !Note: Effective IP address and MTU will be as negotiated by PPP !Note: Any HDLC/Frame-Relay configuration currently does not apply encapsulation ppp ppp ipcp address accept-local ppp authentication client-username admin ppp authentication client-password admin no shutdown top ! ! ! ! Filter Policy configuration ! ! ! ! Dos attack configuration ! ! ! ! System doesn't have IDS License ! IDS configuration may not be effective ! !Snort config
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) Performing Basic Configuration Tasks ! top ! !Customized-Services ! ! ! ! ! ! ! top ! ! ! ! ! DHCP Server Configuration ! service dhcp enable ! ip dhcp pool p1 network 192.168.1.0 255.255.255.0 range 192.168.1.2 192.168.1.254 ! top ! ! ! ! DHCP CLIENT Configuration ! ! ip dhcp client default_client vendor-class-identifier broadband-forum.
Left running head: Chapter name (automatic) top top ! ! !OAM Configuration ! oam top ! ! ! DHCP Relay configuration ! ! end Step 4: You can save the factory default configuration to the startup configuration by using the following command: Example: ALU(config)# write mem Note: In case of reload, the system always boots up with the factory default configuration unless you explicitly save the modified configuration.
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) Performing Basic Configuration Tasks ACCESSING THE OMNIACCESS 5510 USG THROUGH GUI Follow the procedure given below to access and configure the OmniAccess 5510 USG through GUI. Step 1: Open a Web browser from your PC. Step 2: In the address bar/field, type the IP address of the interface obtained from the DHCP server and press the Enter key. Example: http:// http://192.168.1.
Left running head: Chapter name (automatic) CONNECTING THROUGH TELNET Telnet is a user command and an underlying TCP/IP protocol for accessing remote computers. Telnet allows you to log on as a regular user with preset privileges to the specific application and data on that remote computer.
Except on the first page, right running head: Heading1 or Heading1NewPage text (automatic) Obtaining Technical Support CONNECTING THROUGH SSH Secure Shell (SSH) is a Unix-based command interface and protocol for securely getting access to a remote computer. SSH uses the RSA public key cryptography for both connection and authentication.
Left running head: Chapter name (automatic) Alcatel-Lucent 18 OmniAccess 5510 Unified Services Gateway Getting Started Guide Beta Beta