Specifications
OmniAccess 5510 USG - Release Notes
September 2010
Supported Traps
The following traps are supported in 3.0:
Trap Name Platforms Description
aluEGChassisTempTooHigh All The aluEGChassisTempTooHigh is generated when the
chassis temperature (displayed in the “show
chassis”output) goes above the upper threshold limit of
45
0
C.
aluEGMemoryUsageTooHigh
All
The aluEGMemoryUsageTooHigh is generated when
the primary memory usage in the chassis goes above the
threshold limit of 95%.
linkDown All The linkDown trap is generated when the system
recognizes that one of the communication links
represented in the agent's configuration has gone down.
linkUp All The linkUp trap is generated when the system
recognizes that one of the communication links
represented in the agent's configuration has come up.
coldStart All The coldStart trap is generated when the sending
protocol entity is reinitializing itself such that the
agent's configuration or the protocol entity
implementation may be altered.
warmStart All The warmStart trap is generated when the sending
protocol entity is reinitializing itself such that neither
the agent configuration nor the protocol entity
implementation is altered.
authenticationFailure All An authenticationFailure trap is generated when the
sending protocol entity is the addressee of a protocol
message that is not properly authenticated.
dsx1LineStatusChange OmniAccess
5510-TE USG
A dsx1LineStatusChange trap is sent when the
value of an instance dsx1LineStatus changes.
frDLCIStatusChange All The frDLCIStatusChange trap is generated when the
indicated virtual circuit has changed state. It has either
been created or invalidated, or has toggled between the
active and inactive states. If, however, the reason for the
state change is due to the DLCMI going down, per-
DLCI traps are not be generated.
aluEGPPPLinkUp All The PPPlinkUp trap is generated when the system
recognizes that one of the PPP communication links
represented in the agent's configuration has come up.
aluEGPPPLinkDown All The PPPlinkDown trap is generated when the system
recognizes that one of the PPP communication links
represented in the agent's configuration has gone down.
aluEGPkgUpgradeStatusTrap All Trap aluEGPkgUpgradeStatusTrap informs about status
of a software / firmware upgrade.
ieee8021SpanningTreeNewRoot All The ieee8021SpanningTreeNewRoot notification
indicates that the sending agent has become the new
root of the Spanning Tree; the notification is sent by a
bridge soon after its election as the new root. For
example, upon expiration of the topology change timer,
Page 26 of 33 OmniAccess 5510 USG - Release 3.0
032667-10 Rev. A