Common Configuration Tasks
Page 252 7705 SAR OS Basic System Configuration Guide
Entering Edit Mode
To enter the mode to edit timing references, you must enter the begin keyword at the
config>system>sync-if-timing# prompt.
Use the following CLI syntax to enter the edit mode:
CLI Syntax: config>system>sync-if-timing
begin
The following error message displays when the you try to modify sync-if-timing
parameters without entering begin first.
ALU-1>config>system>sync-if-timing>ref1# source-port 1/1/1
MINOR: CLI The sync-if-timing must be in edit mode by calling begin before any
changes can be made.
MINOR: CLI Unable to set source port for ref1 to 1/1/1.
ALU-1>config>system>sync-if-timing>ref1#
Configuring Timing References
The following example shows the command usage:
Example: config>system# sync-if-timing
config>system>sync-if-timing# begin
config>system>sync-if-timing# ref1
config>system>sync-if-timing>ref1# source-port 1/1/1
config>system>sync-if-timing>ref1# no shutdown
config>system>sync-if-timing>ref1# exit
config>system>sync-if-timing# ref2
config>system>sync-if-timing>ref2# source-port 1/1/2
config>system>sync-if-timing>ref2# no shutdown
config>system>sync-if-timing>ref2# exit
config>system>sync-if-timing>commit
The following displays the timing reference parameters:
ALU-1>config>system>sync-if-timing# info
----------------------------------------------
ref-order ref2 ref1
ref1
source-port 1/1/1
no shutdown
exit
ref2
no shutdown
source-port 1/1/2
exit
----------------------------------------------
ALU-1>config>system>sync-if-timing#