User guide

Network Interface (NI) Modules GNI Modules
OmniSwitch 7700/7800 Hardware Users Guide April 2005 page 5-15
Note. Connector and cable information in the above table is dependent on the type of MiniGBIC(s)
installed in the OS7-GNI-U12 module. For a technical breakdown of each MiniGBIC type, refer to “Mini-
GBIC Specifications” on page 5-16.
OS7-GNI-U12/OS7-GNI2-U12 Technical Specifications
Number of MiniGBIC ports 12 (hot-pluggable)
Connector types LC
Standards supported 802.3z; 1000Base-SX, 1000Base-LX
Data rate 1 Gigabit per second (full duplex)
Maximum frame size 9216 bytes
OS7-GNI-U12 modules support jumbo frames (1500 to 9000 bytes)
MAC addresses supported 32000 per Network Interface (NI) module
Connections supported 1000Base-SX, 1000Base-LX or 1000Base-LH70 connection support-
ing multiple uplinks from wire closet switches and supporting a large
number of Gigabit backbone links in core applications.
Fiber optic cables supported Multimode and single mode
Output optical power -9.5 to 0 dBm (multimode)
-11 to -3 dBm (intermediate reach single mode)
0 to +5 dBm (long reach single mode)
Input optical power -17 to 0 dBm (multimode)
-19 to -3 dBm (intermediate reach single mode)
-23 to -3 dBm (long reach single mode)
Cable distances
a
Multimode fiber 220 m
Intermediate reach single mode fiber
10 km
Long reach single mode fiber
70 km
Current draw 2.0 amps at 24 volts
Power 48 watts (approximate)
a. Please note that distances are based on optimal conditions and may decrease depending on such fac-
tors as fiber diameter and quality.