User guide
Network Interface (NI) Modules GNI Modules
OmniSwitch 7700/7800 Hardware Users Guide April 2005 page 5-15
Note. Connector and cable information in the above table is dependent on the type of MiniGBIC(s)
installed in the OS7-GNI-U12 module. For a technical breakdown of each MiniGBIC type, refer to “Mini-
GBIC Specifications” on page 5-16.
OS7-GNI-U12/OS7-GNI2-U12 Technical Specifications
Number of MiniGBIC ports 12 (hot-pluggable)
Connector types LC
Standards supported 802.3z; 1000Base-SX, 1000Base-LX
Data rate 1 Gigabit per second (full duplex)
Maximum frame size 9216 bytes
OS7-GNI-U12 modules support jumbo frames (1500 to 9000 bytes)
MAC addresses supported 32000 per Network Interface (NI) module
Connections supported 1000Base-SX, 1000Base-LX or 1000Base-LH70 connection support-
ing multiple uplinks from wire closet switches and supporting a large
number of Gigabit backbone links in core applications.
Fiber optic cables supported Multimode and single mode
Output optical power -9.5 to 0 dBm (multimode)
-11 to -3 dBm (intermediate reach single mode)
0 to +5 dBm (long reach single mode)
Input optical power -17 to 0 dBm (multimode)
-19 to -3 dBm (intermediate reach single mode)
-23 to -3 dBm (long reach single mode)
Cable distances
a
Multimode fiber ≈ 220 m
Intermediate reach single mode fiber
≈10 km
Long reach single mode fiber
≈ 70 km
Current draw 2.0 amps at 24 volts
Power 48 watts (approximate)
a. Please note that distances are based on optimal conditions and may decrease depending on such fac-
tors as fiber diameter and quality.