Specifications
70
Changing position of inlet
and exhaust fittings
Disassembling the fittings
Horizontal reassembly
Depending on the types of accessories used and the pumping conditions,
these orifices can be fitted vertically on the pump or horizontally as shown on
the diagram below.
Note: The pump is supplied in configuration A.
Unfasten the attachment screw from
the end fitting to be removed.
Unfasten the end fitting and remove
it from its housing along with the
O-ring. In the case of the inlet end
fitting, also remove the inlet filter.
Remove the attachment screw
from the lateral cap and
using a wide screwdriver, remove the
cap.
- Position the end fitting in the
corresponding lateral orifice taking care
to fit the O-ring.
Attach the end fitting with the screw.
In the case of the inlet end fitting, fit the filter at the bottom of the orifice.
- Close unused orifices with plugs and fasten the screws.
In. Exh. In. Exh.
In. Exh. In. Exh.
30
A
B
D
C