Troubleshooting guide
9 — NE maintenance
9-24 Alcatel-Lucent 5620 Service Aware Manager
5620 SAM
System Administrator Guide
Procedure 9-13 To create NE configuration rollback checkpoint files
The checkpoint file storage location must be configured before you can create NE
configuration rollback checkpoint files; see Procedure 9-11. You can also automate NE
configuration rollback checkpoint file creation; see Procedure 9-14.
1 Choose Administration→NE Maintenance→NE Configuration Rollback from the
5620 SAM main menu. The NE Configuration Rollback form opens.
2 To create a checkpoint file:
i Click on the NE Rollback tab.
ii Choose a device and click Properties. The NE Rollback (Edit) form opens.
iii Click on the Checkpoint Files tab.
iv Click Create and confirm. The Create Checkpoint form opens.
v If required, add a comment to the checkpoint file. Click OK. The comment
dialog box closes.
vi Click OK. The Create Checkpoint form opens and the checkpoint is added to
the list form on Checkpoint Files tab.
3 To enable redundant rollback synchronization between the active and standby
CPM:
i Click on the General tab.
ii Perform one of the following:
• To configure automated redundant rollback synchronization, select the
Redundant Rollback Synchronization check box.
• To perform manual redundant rollback synchronization, click
Rollback-Sync Now.
4 Save your changes and close the form.
Note — You can enable redundant rollback synchronization only when
the following conditions are met.
• The rollback file location is CFLASH.
• The device has a standby CPM.
Release 13.0 R2 | May 2015 | 3HE 09815 AAAB TQZZA Edition 01