Troubleshooting guide
5 — 5620 SAM component configuration
Alcatel-Lucent 5620 Service Aware Manager 5-35
5620 SAM
System Administrator Guide
Statistic tab
Allows you to configure the default behavior associated when exporting statistics files on
a 5620 SAM server such as specifying the default log file retention time (applies to
accounting and performance statistics) or log file rollover time (applies to performance
statistics).
5620 SAM Statistics
Management Guide
Allows you to configure the number of JMS client connection checks when exporting
statistics files on a 5620 SAM server that are performed before the auto-deregistration
of the registerLogToFile. This applies to accounting and performance statistics.
5620 SAM XML OSS
Interface Developer
Guide
Bin Alarm tab
Allows you to configure the maximum Bin Alarm limit, reset synchronization time, reset
interval, and alarm severity.
5620 SAM User Guide
Test Manager tab
Allows you to configure the default retention time for dB test results and target test
results and log files performed with the Service Test Manager and which test results are
stored.
5620 SAM User Guide
User Activity tab
Allows you to configure how much user activity log information is stored in the 5620 SAM
db before it purges information and the retention period.
Chapter 7
OLC tab
Allows you to configure the default behavior associated with OLC state of an object that
is undergoing commissioning or maintenance. You can configure the following:
• Enable or disable if the OLC state is automatically set to maintenance when the
following actions occur:
• When the Administrative state is down.
• If the status of the parent object is set to administratively down.
• If the affecting object administrative state is down.
• For scheduled objects set to the maintenance mode, if alarm information should be
created prior to an OLC revert and the lead time of the alarm notification before
reverting. Three OLC time options can be configured for each object.
Additionally, the following applies to this system preference configuration:
• If the Enable Automatic OLC State change parameter is enabled, a Shut Down action
will set the object’s state to Maintenance and a Turn Up action will set the object’s
state to In Service. This state change is also applied to any child objects.
• The Enable Automatic OLC State change parameter applies only to objects which
support the OLC state. It does not apply to routing objects.
Section 15.13
Function or setting Additionally see
(2 of 4)