Specifications

13
3. Save in Memory
This function saves the results of up to 12 tests. Move the cur-
sor (*) to the Save in Memory position and press the right arrow
key on the TS1000. The user must select which of the 12 posi-
tions the results should be saved to, using the up and down
arrow keys to navigate the cursor (*) through memory.
Each memory location number is followed by three characters,
either res or Emp. Res means reserved (there is already a
file saved there) and Emp means empty.
Press the right arrow key to save the latest test results into a
memory location. If the user tries to save the test result to a
memory location that is reserved, the user will be given a
prompt asking if the contents of this memory location should be
overwritten. If the answer is Yes (pressing the right arrow key),
the original saved data will be replaced with the new test
results. If the answer is No (pressing the left arrow key), the
user will be taken back out to the results screen.
Pressing the left arrow will take the user back to the Main Menu.
Ending a Test
To stop a running test or to exit from a completed test, press the
left arrow button on the TS1000. This will return the user to the
main screen.
*Send to PC
Send to Printer
Save in Memory
Press to save
ts1000_015
Select Location#
*#01Res #03Emp
#02Emp #04Emp
Press to save
ts1000_016
Select Location#
Overwrite Res?
Press to confirm
ts1000_017