Datasheet
Alcatel-Lucent Page 54
OmniSwitch 9000
Power Consumption example for OmniSwitch 9700 Power consumption calculation methodology:
(One OS9700 chassis + the fan-tray) + 2 x OS9700-CMM + 8 x OS9-GNI-U24;
Total System Power (“load”): 80watts + 2 x 27watts + 8 x 55watts = 574watts
Total AC input power required is: 765.33 watts (574 watts / 75%)
T
T
o
o
t
t
a
a
l
l
P
P
o
o
w
w
e
e
r
r
C
C
o
o
n
n
s
s
u
u
m
m
p
p
t
t
i
i
o
o
n
n
f
f
o
o
r
r
t
t
h
h
i
i
s
s
c
c
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
i
i
s
s
:
:
7
7
6
6
6
6
w
w
a
a
t
t
t
t
s
s
Power Consumption & Heat Dissipation
examples for the OmniSwitch 9700
Note: for all practical situations, all heat
dissipation calculations are based on Maximum
Power Consumption (Max Power Draw)
Power consumption calculation methodology:
Configuration Example#1:
(One OS9700 chassis + the fan-tray) + 2 x OS9700-CMM + 8 x OS9-GNI-U24;
Total System Power (“load”): 80watts + 2 x 27watts + 8 x 55watts = 574watts
Total AC input power required is: 765.33 watts (574 watts / 75%)
765.33watts x 3.41214 BTU/hr. = 2,611.41 BTU/hr.
T
T
o
o
t
t
a
a
l
l
H
H
e
e
a
a
t
t
D
D
i
i
s
s
s
s
i
i
p
p
a
a
t
t
i
i
o
o
n
n
f
f
o
o
r
r
t
t
h
h
i
i
s
s
c
c
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
i
i
s
s
:
:
2
2
,
,
6
6
1
1
2
2
B
B
T
T
U
U
/
/
h
h
r
r
.
.
Configuration Example#2:
(One OS9700 chassis + the fan-tray) + 2 x OS9700-CMM + 8 x OS9-GNI-C24;
Total System Power (“load”): 80watts + 2 x 27watts + 8 x 51watts = 542watts
Total AC input power required is: 722.66 watts (542 watts / 75%)
722.66watts x 3.41214 BTU/hr. = 2,465.81 BTU/hr.
T
T
o
o
t
t
a
a
l
l
H
H
e
e
a
a
t
t
D
D
i
i
s
s
s
s
i
i
p
p
a
a
t
t
i
i
o
o
n
n
f
f
o
o
r
r
t
t
h
h
i
i
s
s
c
c
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
i
i
s
s
:
:
2
2
,
,
4
4
6
6
6
6
B
B
T
T
U
U
/
/
h
h
r
r
.
.
Configuration Example#3:
(One OS9700 chassis + the fan-tray) + 2 x OS9700-CMM + 8 x OS9-XNI-U2;
Total System Power (“load”): 80watts + 2 x 27watts + 8 x 36watts = 422watts
Total AC input power required is: 562.66 watts (422 watts / 75%)
562.66watts x 3.41214 BTU/hr. = 1,919.87 BTU/hr.
T
T
o
o
t
t
a
a
l
l
H
H
e
e
a
a
t
t
D
D
i
i
s
s
s
s
i
i
p
p
a
a
t
t
i
i
o
o
n
n
f
f
o
o
r
r
t
t
h
h
i
i
s
s
c
c
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
i
i
s
s
:
:
1
1
,
,
9
9
2
2
0
0
B
B
T
T
U
U
/
/
h
h
r
r
.
.
Configuration Example#4:
(One OS9700 chassis + the fan-tray) + 2 x OS9700-CMM + 8 x OS9-GNI-P24;
Total System Power (“load”): 80watts + 2 x 27watts + 8 x 54watts = 566watts
Total AC input power required is: 754.66 watts (566 watts / 75%)
754.66watts x 3.41214 BTU/hr. = 2,575.00 BTU/hr.
T
T
o
o
t
t
a
a
l
l
H
H
e
e
a
a
t
t
D
D
i
i
s
s
s
s
i
i
p
p
a
a
t
t
i
i
o
o
n
n
f
f
o
o
r
r
t
t
h
h
i
i
s
s
c
c
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
i
i
s
s
:
:
2
2
,
,
5
5
7
7
5
5
B
B
T
T
U
U
/
/
h
h
r
r
.
.
Configuration Example#5:
This configuration example includes a fully loaded chassis (OS9700 chassis) +
A PoE Power Shelf (OS9-IP-SHELF) with a total of 4 x 600watts PoE P/S (OS9-IPS-0600A):
Step#1: Calculate the heat dissipated in the main fully loaded chassis:
(One OS9700 chassis + the fan-tray) + 2 x OS9700-CMM + 8 x OS9-GNI-P24;
Total System Power (“load”): 80watts + 2 x 27watts + 8 x 54watts = 566watts
Total AC input power required is: 754.66 watts (566 watts / 75%)
754.66watts x 3.41214 BTU/hr. = 2,575.00 BTU/hr.
Total Heat Dissipation for the fully loaded chassis: 2,575 BTU/hr.
Step#2: Calculate the heat dissipated by the 4 x 600watts PoE P/S (OS9-IPS-0600A):
Total AC input power required per PoE P/S: 800 watts (600 watts / 75%)
Due to inefficiency of each PoE P/S 200watts (800watts – 600watts) is consumed per each PoE P/S:
4 x 200watts = 800watts total is consumed per a fully loaded Power Shelf
800watts x 3.41214BTU/hr. = 2,729.712 BTU/hr.
Total Heat Dissipation for the fully loaded Power Shelf: 2,730 BTU/hr.
Step#3: calculate the total heat dissipation:
T
T
o
o
t
t
a
a
l
l
H
H
e
e
a
a
t
t
D
D
i
i
s
s
s
s
i
i
p
p
a
a
t
t
i
i
o
o
n
n
f
f
o
o
r
r
t
t
h
h
i
i
s
s
c
c
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
i
i
s
s
:
:
2
2
,
,
5
5
7
7
5
5
B
B
T
T
U
U
/
/
h
h
r
r
.
.
+
+
2
2
,
,
7
7
3
3
0
0
B
B
T
T
U
U
/
/
h
h
r
r
.
.
=
=
5
5
,
,
3
3
0
0
5
5
B
B
T
T
U
U
/
/
h
h
r
r
.
.
Configuration Example#6:
This configuration example includes a OS9700-CB-A chassis + x NIs (as described) +
A PoE Power Shelf (OS9-IP-SHELF) with a total of 3 x 600watts PoE P/S (OS9-IPS-0600A):
Step#1: Calculate the heat dissipated in the main chassis:
(OS9700-CB-A: One OS9700 chassis + the fan-tray) + 1 x OS9700-CMM + 5 x OS9-GNI-P24 +
1 x OS9-GNI-U24 + 2 x OS9-GNI-C24;
Total Sys Pwr (“load”): 80watts + 1 x 27watts + 5 x 54watts + 1 x 55watts + 2 x 51watts = 534watts
Total AC input power required is: 712 watts (534watts / 75%)
712watts x 3.41214 BTU/hr. = 2,429.44 BTU/hr.
Total Heat Dissipation for the fully loaded chassis: 2,430 BTU/hr.
Step#2: Calculate the heat dissipated by the 3 x 600watts PoE P/S (3 x OS9-IPS-0600A):
The PoE IP Shelf (OS9-IP-SHELF) power consumption is: Negligible
Total AC input power required per PoE P/S: 800 watts (600 watts / 75%)
Due to inefficiency of each PoE P/S 200watts (800watts – 600watts) is consumed per each PoE P/S:
3 x 200watts = 600watts total is consumed per a fully loaded Power Shelf
600watts x 3.41214BTU/hr. = 2,047.28 BTU/hr.
Total Heat Dissipation for the fully loaded Power Shelf: 2,048 BTU/hr.
Step#3: calculate the total heat dissipation:
T
T
o
o
t
t
a
a
l
l
H
H
e
e
a
a
t
t
D
D
i
i
s
s
s
s
i
i
p
p
a
a
t
t
i
i
o
o
n
n
f
f
o
o
r
r
t
t
h
h
i
i
s
s
c
c
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
i
i
s
s
:
:
2
2
,
,
4
4
3
3
0
0
B
B
T
T
U
U
/
/
h
h
r
r
.
.
+
+
2
2
,
,
0
0
4
4
8
8
B
B
T
T
U
U
/
/
h
h
r
r
.
.
=
=
4
4
,
,
4
4
7
7
8
8
B
B
T
T
U
U
/
/
h
h
r
r
.
.