Datasheet

Alcatel-Lucent Page 13
OmniSwitch 9000
OmniSwitch 9600 Chassis Technical Specifications
OmniSwitch 9600
The OmniSwitch 9600 is a 5-slot large enterprise core switch.
The OmniSwitch 9600 offers up to 96 Gigabit Ethernet ports
and can also be equipped with up to
8/24 (Fully-populated with 4 x OS9-XNI-U2/OS9-XNI-U6
modules, with each XNI containing two/six XFPs) 10-Gigabit
Ethernet ports. The OmniSwitch 9600 chassis contains the
following major components:
• Four Network Interface (NI) module slots
• One Chassis Management Module (CMM) slots
• Power supply bay holding up to two power supplies
• Fan tray with four fans
Total slots per chassis
5
Total slots for network interface (NI) modules
4
Total slots for Chassis Management Module (CMM)
1
Total bays for power supplies
2
Total 10/100/1000BASE-T copper 10/100/1000Mbps Ethernet ports available
96 (Fully-populated with 4 x OS9-GNI-C24 modules)
Total 10/100/1000BASE-T copper 10/100/1000Mbps Ethernet ports with PoE available
96 (Fully-populated with 4 x OS9-GNI-P24 modules)
Total 1000BASE-X fiber Gigabit Ethernet ports available
96 (Fully-populated with 4 x OS9-GNI-U24 modules)
Total 10GBASE-X 10-Gigabit Ethernet ports available
Wire-rate: 8 (Fully-populated with 4 OS9-XNI-U2 modules,
with each XNI containing two XFPs.)
Oversubscribed: 24 (Fully-populated with 4 OS9-XNI-U6
modules, with each XNI containing six XFPs.)
The oversubscription ratio is: 2.5:1
Power Consumption
OS9600-Chassis & Fans = 42watts
Full Duplex support
Full duplex is supported on Gigabit Ethernet ports and
10-Gigabit Ethernet ports.
Environmental Requirements
OmniSwitch 9000 Series switches have the following
environmental and airflow requirements:
• The installation site must maintain a temperature between
and 45° Celsius (32° and 113° Fahrenheit) and not exceed 95
percent maximum humidity (non-condensing) at any time.
• Be sure to allow adequate room for proper air ventilation at
the front, back, and sides of the switch. No clearance is
necessary at the top or bottom of the chassis.
Electrical Requirements
OmniSwitch 9000 Series switches have the following general
electrical requirements:
• Each switch requires one grounded electrical outlet for each
power supply installed in the chassis (up to three for
OS9700 switches; up to two for OS9600 switches).
OmniSwitch 9000 Series switches offer both AC and DC
power supply support. For switches using AC power
connections, each supplied AC power cord is 2 meters
(approximately 6.5 feet) long. Do not use extension cords.
Redundant AC Power. It is recommended that each AC
outlet reside on a separate circuit. With redundant AC, if a
single circuit fails, the switch’s remaining power supplies (on
separate circuits) are likely to remain unaffected and can,
therefore, continue operating.
OmniSwitch 9600 Chassis Dimensions
Chassis Width
19 inches
Height
9.575 inches
Height (rack units)
5.47 RU
Chassis Depth
14.432 inches