User Guide
ALC ETL
Alcatel OmniPCX 4400
SBC Alcatel 4059 Section 4 - SBC Alcatel 405 9
Installation - Software
3.7. Configuring physical access on the PC
In
this screen, the operator configures physical access set tings for the newly installed application with:
-th
e name identifying access,
-ch
oice of protocol. For an instal lation using the 4059 MAC applicatio n and the TA-MMK un it,
ph
ysical access must be configured with PAC/PC protocol.
No
te: with the TA-MAC unit, access must be configured with MAC/PC protocol.
-th
e choice of port (com1 to 4) for the connection between PC and set.
-th
e choice of MPB mode (set by default at "enable super & combined").
Cl
ick “Ok” to confirm.
R
emark: this step is no t performed in the case of a software upgrade. If the attendant wishes to
m
odify exisiting access parameters, the Alcatel ABCA applications c onfigurator window (shown
b
elow) must be used.
T
o display this window, click the menu Start >> Programs >> Alcatel 4400 A pplications > >
Setup tool for ABCA applicatio ns. When the window is displaye d, select the application then click
“Access... “.
3.8. Configuration rep ort
The following screen is used to check the correspondence betw een the "applications" (or sessions) and
the physi cal access es.
4.14 Ref.3BA19919ENAA Ed.03