Chapter 8: Visualization
■ Layer 7 Event Table
Configuring Visualization
For the most part, you do not need to explicitly configure visualization in order to see
data in OmniVista SafeGuard Manager. SafeGuard OS does however, provide some
options for how you push information to OmniVista SafeGuard Manager. To keep
changes to the configuration after a reboot, save the running configuration to the startup
configuration using the write memory command.
Setting Up the Controller or Switch for OmniVista SafeGuard
Manager
The OmniVista SafeGuard Manager server establishes and maintains the connection with
the SafeGuard device. A SafeGuard device allows up to four OmniVista SafeGuard
Manager servers to be simultaneously connected, which is the default. The mgmt-server
max-servers command allows you to specify the number of OmniVista SafeGuard
Manager servers connected to the SafeGuard device. To change the number of
management servers, use this command in Global Configuration mode:
mgmt-server max-servers number
In the following example, we limit the number of connections to 3 OmniVista SafeGuard
Manager servers:
(SafeGuardOS) #configure terminal
(SafeGuardOS) (config) #mgmt-server max-servers 3
(SafeGuardOS) (config) #exit
(SafeGuardOS) #
You can verify the number of servers configured using the show mgmt-server max-
server command. For more information, see Showing Server Connections on page 339.
Setting the Update Interval for OmniVista SafeGuard Manager
You can change the update interval for the SafeGuard device to send refreshed
information to OmniVista SafeGuard Manager. The default time is 30 seconds, but valid
range are from 15 to 120 seconds. Setting the interval to a shorter time interval causes
more frequent updates and more overhead on OmniVista SafeGuard Manager; longer
intervals use more memory on the device process.
Syntax Description number The number of OmniVista SafeGuard
Manager servers connected to the
SafeGuard device. Valid entries are from 1